Intelligence for machine
Efficient for production

YYR80 Series High Pressure Regulator
YYR80 was research and development independently by our company in 2016.

Function:
Reduce the high pressure gas (80bar-100bar) to low pressure gas (1bar-10bar)
Characteristic:
Working pressure is generally a stable value
Working pressure can be adjusted
Small size, light weight, easy to carry
Safety air pressure can be set to prevent danger (120bar automatic blasting)
Gas cylinders can be directly inserted into the regulator, and can also be used for portable pneumatic products, such as air guns, pneumatic screwdrivers
It is often used with high-pressure gas cylinders

Application Industry:
Various inflatable devices, beer machines, aquariums, paintball guns and other industries
Matters needing attention:
No lubrication is required during use
Do not use the pressure beyond its scope of use
When the outlet air volume is significantly reduced, the filter element shall be replaced in time
Pay attention to the use of media and try to avoid chlorine, carbon compounds, oxidizing acids, bases and other substances
Specification:
Model
| YYR80
|
Air inlet port size
| G5/16"
| G1/2"
|
| Air outlet port size | G1/8"
| G1/4"
|
Ambient temperature(℃)
| -10~55℃
|
| Media temperature(℃) | -10~55℃ |
Air inlet pressure(Mpa)
| 8
|
Operating pressure(Mpa)
| 0.1~0.8
|
Security pressure(Mpa)
| 12
|
Medium
| CO₂
|
Overall Dimension:

Installation and use:
Before use, pay attention to check whether it is damaged during transportation, and then install it for use
During installation, please pay attention to the gas flow direction (pay attention to the "→" direction) and whether the nozzle tooth shape is correct
Please pay attention to whether the installation conditions meet the technical requirements (such as "working pressure", "service temperature range")
Clean or replace the filter element regularly, and the use of pressure regulating valve shall follow the principle from large to small
Pay attention to precautions. Install dust boots at the air inlet and outlet when it is removed and not in use
Matters needing attention:
No lubrication is required during use
Do not use the pressure beyond its scope of use
When the outlet air volume is significantly reduced, the filter element shall be replaced in time
Pay attention to the use of media and try to avoid chlorine, carbon compounds, oxidizing acids, bases and other substances

Patent certificater